Skip to content

AnyBodyCodec: A Shared Native Interface for Body-Model Conversion, Extension, and Humanoid Control

arXiv Robotics — research abstracts1Qianxing Li

This research presents AnyBodyCodec, a system that learns a shared representation for converting between incompatible parametric body models (MHR, SMPL-X, SOMA) to enable reuse of frozen humanoid control policies. The converter achieves an input-reference MPJPE of 16.801 mm across six cross routes on an RTX 4090 and supports three measured conversion routes in 7.43-7.67 ms. Under a matched PPO budget, aligned slots support 60.78% full-action success across three formats. The controller is deployed qualitatively on a physical G1 robot through three visual front ends.

arXiv:2611.27397v1 Announce Type: new Abstract: Parametric body models expose incompatible pose and shape controls, tying humanoid policies to particular input formats. AnyBodyCodec learns a shared representation through native conversion, then reuses it for new body models and control with its core frozen. Encoders map MHR, SMPL-X, and SOMA to aligned slots; native decoders recover target controls. The 1.090M-parameter converter covers nine routes and reaches 16.801 mm input-reference MPJPE across six cross routes: the 2.887M Transformer bank reaches 16.390 mm and its parameter-matched version 18.866 mm. Three measured routes take 7.43-7.67 ms on an RTX 4090. Adding ANNY shows that comparable conversion accuracy can accompany different action consistency under one frozen controller. Under a matched PPO budget, aligned slots support 60.78% full-action success across three formats. Separate 160-hour training reaches 66.10% source-weighted validation success, and the controller is deployed qualitatively on a physical G1 through three visual front ends. Together, these results establish reuse through both native geometric fidelity and downstream policy compatibility.

Source notes

  1. AnyBodyCodec: A Shared Native Interface for Body-Model Conversion, Extension, and Humanoid Control↩
Source evidence

Reported by the source; not independently verified.

training hours
160 hours[2]
MPJPE error
16.801[3]
MPJPE error
16.39[3]
MPJPE error
18.866[3]
conversion latency
7.43–7.67[3]
  1. port 60.78% full-action success across three formats. Separate 160-hour training reaches 66.10% source-weighted validation success, and the controller is deployed qualitatively on a physical G1 through three visual front ends. Together, these results establish reuse through both native geometric fidelity and downstream policy compatibility.
    Exact source↩
  2. ter converter covers nine routes and reaches 16.801 mm input-reference MPJPE across six cross routes: the 2.887M Transformer bank reaches 16.390 mm and its parameter-matched version 18.866 mm. Three measured routes take 7.43-7.67 ms on an RTX 4090. Adding ANNY shows that comparable conversion accuracy can accompany different action consistency under one frozen controller. Under a matched PPO budget, aligned slots sup
    Exact source↩

Automatically extracted; no manual editorial approval recorded.

Article details
Signal

The paper introduces AnyBodyCodec, a shared native interface for converting between parametric body models (MHR, SMPL-X, SOMA) to enable reuse of frozen humanoid controllers across different formats. The authors report specific metrics including MPJPE errors on an RTX 4090 and action success rates under matched PPO budgets, with qualitative deployment on a physical G1 robot.

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).