China's Voice: Domestic Neurointerventional Robotic System PANVIS STAR® Completes Validation of Five Major Neurointerventional Procedures in Preclinical Animal Study
[China's Voice] Preclinical Animal Study: Domestic Neurointerventional Robotic System PANVIS STAR® Completes Validation of Five Major Neurointerventional Procedures
A preclinical animal study conducted by Shenzhen Institute of Advanced Biomedical Robot Co., Ltd. in collaboration with Professor Jianmin Liu's team at Shanghai Changhai Hospital has validated the capabilities of the neurointerventional robotic system PANVIS STAR®. The system successfully completed five major procedures, including cerebral angiography, aneurysm coil embolization, flow diverter deployment, vertebral artery stenting, and carotid artery stenting, with no device-related complications or vascular injury. The study, published in the Journal of Robotic Surgery, marks a significant step toward treatment-capable robotic systems in neurointerventional procedures.
Full article
Article text is not available for this item. Read it at the original source.
Read full article at sourcemanilatimes.net · Opens in a new tab; source language may differ.
What the source reports
Publisher-reported claims, with original evidence. These results have not been independently verified by RoboSignal.
Reported numbers
procedures completed
5
View original evidence
pleted for five major categories of procedures: cerebral angiography and establishment of therapeutic access, aneurysm coil embolization, flow diverter (FD) deployment, vertebral artery stenting, and carotid artery stenting. All procedures were successful, with no device-related complications or vascular injury. The entire process, from guidewire and catheter superselective navigation to implant deployment, was perfo
Open source S4mean procedural time
13 minutes
View original evidence
e balloon-expandable stent to the vertebral artery, with the robot maintaining distal wire stabilization during balloon inflation, deflation and retrieval Loading of the stent and microguidewire into the Y valve; balloon inflation 13 min Carotid artery stenting (CAS) Delivery and retrieval of the cerebral protection device (Spider FX), navigation of the balloon and stent, and deployment of the self-expanding stent Lo
Open source S18procedures completed
5
View original evidence
of five surgically created aneurysms were allocated to coiling alone (n = 2), FD implantation (n = 2), and coiling + FD (n = 1). In addition, one right vertebral artery (V1 segment) and one right common carotid artery were utilized for vertebral artery balloon-expandable stent angioplasty and CAS, respectively. Since the objective was to validate technical feasibility rather than to simulate pathological stenosis, no
Open source S14
- paper: not_reported
Source excerpts and review record
Automatically extracted; no manual editorial approval recorded.
pleted for five major categories of procedures: cerebral angiography and establishment of therapeutic access, aneurysm coil embolization, flow diverter (FD) deployment, vertebral artery stenting, and carotid artery stenting. All procedures were successful, with no device-related complications or vascular injury. The entire process, from guidewire and catheter superselective navigation to implant deployment, was perfo
Open source S4
ant technical complications or vascular damage. The mean procedural time of each procedure was as follows: Procedure Core steps completed by the robot Steps still performed manually Mean procedural time Diagnostic cerebral angiography Navigation of the 5F catheter and 0.035-inch guidewire from the femoral sheath to the target vessel, completing bilateral carotid and vertebral angiography Insertion of the arterial she
Open source S16
e balloon-expandable stent to the vertebral artery, with the robot maintaining distal wire stabilization during balloon inflation, deflation and retrieval Loading of the stent and microguidewire into the Y valve; balloon inflation 13 min Carotid artery stenting (CAS) Delivery and retrieval of the cerebral protection device (Spider FX), navigation of the balloon and stent, and deployment of the self-expanding stent Lo
Open source S18
of five surgically created aneurysms were allocated to coiling alone (n = 2), FD implantation (n = 2), and coiling + FD (n = 1). In addition, one right vertebral artery (V1 segment) and one right common carotid artery were utilized for vertebral artery balloon-expandable stent angioplasty and CAS, respectively. Since the objective was to validate technical feasibility rather than to simulate pathological stenosis, no
Open source S14
Source:Surgical robotics — News discovery · manilatimes.net