Skip to content
arXiv Robotics — research abstracts· Dongho Yee, Juahn Oh, Jinseok Lee, Jiyul Lee, Yechan Seo, Seong Jeong, Minsung Kim, Seonho Shim, Younghoon Noh, Hyuk Choi, Youngbin Kong, Kyu Eun Lee, Hyoun-Joong Kong·· 23 hours agoSignalEditorial score88

From Instrument-Mounted Demonstrations to In-Vivo Execution: Learning Bimanual Laparoscopic Appendectomy Without Robot-Collected Demonstrations

From Instrument-Mounted Demonstrations to In-Vivo Execution: Learning Bimanual Laparoscopic Appendectomy Without Robot-Collected Demonstrations

Summary

This research presents an end-to-end pipeline for training a surgical robot policy using motion data captured from standard laparoscopic instruments. The system uses inertial, time-of-flight, and Hall sensors to track instrument state without external cameras. A diffusion policy is trained on both ex-vivo and in-vivo demonstrations, achieving appendectomy in three of four live rabbits. The robot serves as a timing reference and executor, with no demonstration collection.

Editorial context

This paper demonstrates the feasibility of training a bimanual surgical robot policy using instrument-mounted demonstrations without external cameras or trackers, validated on live animals. The approach leverages inertial and time-of-flight sensors for motion capture and uses a diffusion policy trained on both ex-vivo and in-vivo data.

Source: arXiv Robotics — research abstracts · Read original article ↗

Loading article text…

What the source reports

Publisher-reported claims, with original evidence. These results have not been independently verified by RoboSignal.

Reported numbers

  • live rabbits

    4

    View original evidence
    tions we train a diffusion policy with a fine-tuned DINOv3 backbone, selecting its design by closed-loop rollouts in a physics simulator reconstructed from depth maps of an ex-vivo rabbit appendix. The policy is then retrained on 849 in-vivo demonstrations from four live rabbits and deployed on four additional live rabbits with electrosurgery armed. With the surgeon selecting the surgical phase, the policy completed
    Open source S4
  • additional live rabbits

    4

    View original evidence
    tions we train a diffusion policy with a fine-tuned DINOv3 backbone, selecting its design by closed-loop rollouts in a physics simulator reconstructed from depth maps of an ex-vivo rabbit appendix. The policy is then retrained on 849 in-vivo demonstrations from four live rabbits and deployed on four additional live rabbits with electrosurgery armed. With the surgeon selecting the surgical phase, the policy completed
    Open source S4
  • paper: not_reported
  • code: not_reported
  • weights: not_reported
  • dataset: not_reported
Source excerpts and review record

Automatically extracted; no manual editorial approval recorded.

tions we train a diffusion policy with a fine-tuned DINOv3 backbone, selecting its design by closed-loop rollouts in a physics simulator reconstructed from depth maps of an ex-vivo rabbit appendix. The policy is then retrained on 849 in-vivo demonstrations from four live rabbits and deployed on four additional live rabbits with electrosurgery armed. With the surgeon selecting the surgical phase, the policy completed

Open source S4

ntroduce a surgical instrument-state logger that mounts on the shaft of a standard laparoscopic instrument and recovers its pose and jaw state from an inertial sensor, a time-of-flight sensor and a Hall sensor, with no external camera or tracker. A data pipeline measures the latency of every sensor channel against a robot ground truth and aligns the channels before forming observation-action pairs. On these demonstra

Open source S3

Source:arXiv Robotics — research abstracts · arxiv.org