Skip to content
arXiv Robotics — research abstracts· Hao Wu, Haotian Guo, Yu Feng, Yutong Wang, Jianshu Zhou·· 5 days agoSignalEditorial score75

LumiTac: Compact, High-Rate Six-Axis Optical Tactile Sensing for Human-Robot Interaction

LumiTac: Compact, High-Rate Six-Axis Optical Tactile Sensing for Human-Robot Interaction

Summary

This paper introduces LumiTac, a low-profile, camera-free optoelectronic tactile sensor that integrates six-axis force and moment sensing.

Editorial context

The study presents LumiTac, a compact optoelectronic tactile sensor with independent testing showing R-squared values between 0.9657 and 0.9941 for force reconstruction and an average update rate of 303.57 Hz.

Source: arXiv Robotics — research abstracts · Read original article ↗

Loading article text…

What the source reports

Publisher-reported claims, with original evidence. These results have not been independently verified by RoboSignal.

Reported numbers

  • force measurement error

    0.054–0.19

    View original evidence
    els. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small for
    Open source S4
  • moment measurement error

    0.304–1.419

    View original evidence
    els. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small for
    Open source S4
  • update rate

    303.57

    View original evidence
    els. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small for
    Open source S4
  • software processing latency

    0.722

    View original evidence
    els. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small for
    Open source S4
  • sensor weight

    <2

    View original evidence
    osing circuit boards coupled through translucent silicone. Load-induced interlayer motion modulates the internal light field under compression, shear, bending, and torsion. The sensing head measures 12 mm in diameter and 4.75 mm in thickness, weighs less than 2 g, and has a component cost of approximately USD 7. A compact multilayer perceptron reconstructs three force and three moment components from 20 optical chann
    Open source S3
  • sensor cost

    7

    View original evidence
    osing circuit boards coupled through translucent silicone. Load-induced interlayer motion modulates the internal light field under compression, shear, bending, and torsion. The sensing head measures 12 mm in diameter and 4.75 mm in thickness, weighs less than 2 g, and has a component cost of approximately USD 7. A compact multilayer perceptron reconstructs three force and three moment components from 20 optical chann
    Open source S3
  • paper: not_reported
Source excerpts and review record

Automatically extracted; no manual editorial approval recorded.

els. Independent testing yielded coefficients of determination (R-squared) of 0.9657-0.9941, with mean absolute errors of 0.054-0.190 N for forces and 0.304-1.419 mN m for moments. Online prediction achieved an average update rate of 303.57 Hz and a median software processing latency of 0.722 ms. Experiments involving combined loading, light weights, and rapid tapping evaluated load tracking, sensitivity to small for

Open source S4

osing circuit boards coupled through translucent silicone. Load-induced interlayer motion modulates the internal light field under compression, shear, bending, and torsion. The sensing head measures 12 mm in diameter and 4.75 mm in thickness, weighs less than 2 g, and has a component cost of approximately USD 7. A compact multilayer perceptron reconstructs three force and three moment components from 20 optical chann

Open source S3

Source:arXiv Robotics — research abstracts · arxiv.org

Timezone · UTC