Modelling the human-exoskeleton interaction interface - Benchmarking MuJoCo's deformable model

arXiv Robotics — research abstracts1Lisette Masselink, Xiaolong Zhu Thomas George Thuruthel, Mohamed Irfan Refai

This research abstract presents a benchmarking study comparing MuJoCo's flexcomp Saint Venant-Kirchhoff and Stable Neo-Hookean models against COMSOL's Yeoh model for simulating human soft tissue in an exoskeleton interface.

arXiv:2611.24008v1 Announce Type: new Abstract: The human-exoskeleton interaction interface, consisting of the exoskeleton attachment and the underlying human soft tissue, can affect the transfer of assistance. MuJoCo's \textit{flexcomp} has been previously used to model the soft tissue, but its accuracy has not been benchmarked against a finite element model. We benchmarked the \textit{flexcomp} Saint Venant-Kirchhoff (StVK) and Stable Neo-Hookean (SNH) models against COMSOL's Yeoh model in three cases: \textit{case 1}) spherical indentation, \textit{case 2}) compression, and \textit{case 3}) compression of a thigh. We compared force and strain energy as a function of indentation depth, hysteresis and computation time. MuJoCo's models capture force trends with a correlation of 0.97-0.99, but showed a stiffer response, which could be attributed to the volumetric locking of the linear finite elements. The MuJoCo models systematically underestimated hysteresis as MuJoCo's Rayleigh damping could not substitute a viscoelastic model. Moreover, MuJoCo's computational advantage was speed dependent: it was 2-2.5 times faster for spherical indentation, but COMSOL was faster for the other cases, which have more degrees of freedom and contacts. Although MuJoCo's \textit{flexcomp} offers a combination of soft-tissue modelling and multibody dynamics, the limitations regarding the stiffening and hysteresis should be addressed to be used for the analysis of the human-exoskeleton interaction interface.

Source notes

  1. Modelling the human-exoskeleton interaction interface - Benchmarking MuJoCo's deformable model↩
Source evidence

Reported by the source; not independently verified.

correlation
0.97–0.99[2]
speed_ratio
2–2.5[3]
  1. ff (StVK) and Stable Neo-Hookean (SNH) models against COMSOL's Yeoh model in three cases: \textit{case 1}) spherical indentation, \textit{case 2}) compression, and \textit{case 3}) compression of a thigh. We compared force and strain energy as a function of indentation depth, hysteresis and computation time. MuJoCo's models capture force trends with a correlation of 0.97-0.99, but showed a stiffer response, which cou
    Exact source↩
  2. ld be attributed to the volumetric locking of the linear finite elements. The MuJoCo models systematically underestimated hysteresis as MuJoCo's Rayleigh damping could not substitute a viscoelastic model. Moreover, MuJoCo's computational advantage was speed dependent: it was 2-2.5 times faster for spherical indentation, but COMSOL was faster for the other cases, which have more degrees of freedom and contacts. Althou
    Exact source↩

Automatically extracted; no manual editorial approval recorded.

Article details
Signal

The study benchmarks MuJoCo's soft tissue models against a finite element model, finding high correlation in force trends but noting systematic underestimation of hysteresis and stiffer responses due to volumetric locking.