This research presents Neural Fidelity Calibration (NFC), a framework based on conditional flow matching that infers simulator physical parameters and residual fidelity directly from a robot's execution data. The system uses an anomaly detector to determine when recalibration is needed and employs an exploration policy to modulate uncertainty. Tested across five robot platforms with up to 39 calibrated parameters, NFC achieved the most accurate posterior distributions compared to baselines. In physical outdoor experiments involving a wheeled robot navigating snow, mud, and wet grass after an axle failure, NFC increased rough-terrain navigation success from 26% to 70% while reducing orientation jerk by 88%.

arXiv:2611.28260v1 Announce Type: new Abstract: A policy that transfers from simulation to a lab robot often fails in the field. Calibrating a simulator from real-world data typically targets only a few hand-picked parameters, and even calibrated simulators fail to capture unmodeled dynamics, while environments reconstructed via onboard perception inherit sensing noise and artifacts. We propose Neural Fidelity Calibration (NFC), a framework based on conditional flow matching that infers online, directly from a robot's execution data, both simulator physical parameters and residual fidelity - the remaining dynamics discrepancy and the gap between perceived and true environment geometry. A simulation-trained anomaly detector determines when recalibration or fine-tuning is required using onboard sensory signals alone, while an exploration policy actively modulates posterior uncertainty using optimism in the face of uncertainty. Across five robot platforms with up to 39 calibrated parameters and a 128x128 residual terrain map, NFC achieves the most accurate posterior distributions compared to established simulation-based inference baselines. In physical outdoor experiments with a wheeled robot suffering an axle failure across snow, mud, and wet grass, NFC increases rough-terrain navigation success from 26% to 70% while reducing orientation jerk by 88%.

Source notes

  1. Neural Fidelity Calibration: Turning Field Anomalies into Simulation Fine-Tuning↩
Source evidence

Reported by the source; not independently verified.

  1. oration policy actively modulates posterior uncertainty using optimism in the face of uncertainty. Across five robot platforms with up to 39 calibrated parameters and a 128x128 residual terrain map, NFC achieves the most accurate posterior distributions compared to established simulation-based inference baselines. In physical outdoor experiments with a wheeled robot suffering an axle failure across snow, mud, and wet
    Exact source
  2. grass, NFC increases rough-terrain navigation success from 26% to 70% while reducing orientation jerk by 88%.