Skip to content

Phase-Conditioned Action Contracts for Auditable Microsurgical Control

arXiv Robotics — research abstracts1Jiaxi You, Yiwei Shi, Yanlin Li, Rihui Song, Weibing Li, Kai Huang, Weiru Liu

This research introduces a method to handle action-semantic shifts in staged robotic procedures by separating learned action proposals from deterministic command formation.

arXiv:2611.29426v1 Announce Type: new Abstract: Staged robotic procedures may reuse a fixed-dimensional policy output even though the admissible motions and physical meanings of its coordinates change across phases. We call this action-semantic shift. To address it, we propose a phase-conditioned executable policy that separates learned action proposal from deterministic command formation. Phase-specific heads generate proposals, while an action contract removes inadmissible components, enforces state-dependent bounds, and decodes the remaining action into phase-dependent task-space commands. We further introduce failure-focused local repair and a read-only provenance trace for exact command replay and rule-level auditing. Across three held-out retinal-injection evaluation blocks, our method achieves $94.27\pm0.64\%$ procedural completion and $64.40\pm2.43\%$ success within $35\,\mu\mathrm{m}$, with no hard violations. Applying the contract and decoder to the same frozen Correction network raises completion from $12.27\%$ to $90.47\%$. The trace exactly reconstructs 96,350 commands, and all 1,996 binding interventions follow their declared effects. These results show the importance of explicit executable action semantics for auditable staged microsurgical control.

Source notes

  1. Phase-Conditioned Action Contracts for Auditable Microsurgical Control↩
Source evidence

Reported by the source; not independently verified.

commands
96,350[3]
interventions
1,996[3]
  1. te proposals, while an action contract removes inadmissible components, enforces state-dependent bounds, and decodes the remaining action into phase-dependent task-space commands. We further introduce failure-focused local repair and a read-only provenance trace for exact command replay and rule-level auditing. Across three held-out retinal-injection evaluation blocks, our method achieves $94.27\pm0.64\%$ procedural
    Exact source
  2. completion and $64.40\pm2.43\%$ success within $35\,\mu\mathrm{m}$, with no hard violations. Applying the contract and decoder to the same frozen Correction network raises completion from $12.27\%$ to $90.47\%$. The trace exactly reconstructs 96,350 commands, and all 1,996 binding interventions follow their declared effects. These results show the importance of explicit executable action semantics for auditable stage
    Exact source↩

Automatically extracted; no manual editorial approval recorded.

Article details
Signal

The study presents a phase-conditioned executable policy and action contract framework for microsurgical robotics, demonstrating improved procedural completion rates in retinal-injection tasks while maintaining auditable command traces.

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).