Skip to content
Surgical robotics — News discovery·· 4 days agoEditorial score35

Robotic platform rebuilds bladder neck and repairs rectal fistula in single prostatectomy complication case

Robot Surgery Rebuilds Bladder Neck and Repairs Rectal Fistula After Prostatectomy

Summary

A Da Vinci system assisted surgeons to reconstruct a new bladder neck and close a vesicorectal fistula in one patient. One year later, the patient showed normal urination, continence, and no recurrence of complications. This single-case report published in BMC Urology indicates feasibility but does not establish general success rates or long-term durability.

Full article

Article text is not available for this item. Read it at the original source.

Read full article at source

bioengineer.org · Opens in a new tab; source language may differ.

What the source reports

Publisher-reported claims, with original evidence. These results have not been independently verified by RoboSignal.

Reported numbers

  • peak urine flow

    24.5

    View original evidence
    Surgeons in China have reported a single-case operation in which a robotic platform was used to rebuild a patient’s bladder neck and close an abnormal connection between the bladder and rectum at the same time. The 59-year-old man had developed both problems after radical prostatectomy. One year after the combined repair, he was passing urine normally, was continent, and had a measured peak urine flow of 24.5 millili
    Open source S2
  • peak urine flow

    24.5

    View original evidence
    voided normally and maintained urinary continence, with a Qmax of 24.5 millilitres per second, a value within the range expected for unobstructed urination. No recurrence of the stricture or the fistula was documented, and no complications were reported. The authors conclude that robot-assisted transabdominal bladder neck reconstruction combined with vesicorectal fistula repair is a feasible and effective minimally
    Open source S8
  • millilitres per second

    24.5

    View original evidence
    voided normally and maintained urinary continence, with a Qmax of 24.5 millilitres per second, a value within the range expected for unobstructed urination. No recurrence of the stricture or the fistula was documented, and no complications were reported. The authors conclude that robot-assisted transabdominal bladder neck reconstruction combined with vesicorectal fistula repair is a feasible and effective minimally
    Open source S8
  • paper: not_reported
Source excerpts and review record

Automatically extracted; no manual editorial approval recorded.

Surgeons in China have reported a single-case operation in which a robotic platform was used to rebuild a patient’s bladder neck and close an abnormal connection between the bladder and rectum at the same time. The 59-year-old man had developed both problems after radical prostatectomy. One year after the combined repair, he was passing urine normally, was continent, and had a measured peak urine flow of 24.5 millili

Open source S2

voided normally and maintained urinary continence, with a Qmax of 24.5 millilitres per second, a value within the range expected for unobstructed urination. No recurrence of the stricture or the fistula was documented, and no complications were reported. The authors conclude that robot-assisted transabdominal bladder neck reconstruction combined with vesicorectal fistula repair is a feasible and effective minimally

Open source S8

neck, the diseased structure was abandoned entirely. A new bladder neck was created on the anterior bladder wall, and this freshly constructed outlet was joined to the urethra in a tension-free anastomosis, meaning the connection is made without pulling or stretch on the suture line, a principle regarded as important for healing and for reducing the risk that the join narrows again. At one-year follow-up, the patient

Open source S7

invasive option for this difficult post-prostatectomy condition. The evidence behind that conclusion has clear limits. This is a single case report, published as an accepted manuscript shared early and subject to further edits before the final version of record. A favourable outcome in one patient demonstrates feasibility in that patient; it does not establish how often the technique would succeed across a wider popu

Open source S9

lation, how it compares with alternative strategies, or which patients are suitable candidates. Longer-term durability also remains an open question for future cases to address. Subject of Research: Robotic bladder neck reconstruction with vesicorectal fistula repair after radical prostatectomy Article Title: Robot-assisted bladder neck reconstruction for vesicourethral anastomotic stricture complicated with vesicore

Open source S10

ctal fistula after radical prostatectomy: a case report Article References: Pan, Y., Ni, K., Huang, J., & Song, L. (2026). Robot-assisted bladder neck reconstruction for vesicourethral anastomotic stricture complicated with vesicorectal fistula after radical prostatectomy: a case report. BMC Urology . https://doi.org/10.1186/s12894-026-02314-y Image Credits: AI Generated DOI: 10.1186/s12894-026-02314-y Keywords: radi

Open source S11

cal prostatectomy, vesicourethral anastomotic stricture, vesicorectal fistula, robotic surgery, bladder neck reconstruction, Da Vinci robotic system, urinary continence, case report, BMC Urology, minimally invasive surgery, Robot-assisted, bladder

Open source S12

Source:Surgical robotics — News discovery · bioengineer.org