arXiv Robotics — research abstracts· Li Guan, Rachael Granberry, Sahar Aseeri, Sahar Rostami, Taylor Niehues, Sai Dhanooshi Marri, Mia Huang, Dingtian Zhang, Ziyi Kou, Jason Pursel, Eric Whitmire, Vatsal Mehta, Ashish Deshpande, Tristan Trutna, Reed Belcher, Emelia Black, Julian Blake, Roger Boldu, Sean Bonaventure, Einar Boyovich, Jordan Brennan, Elizabeth Casillas, David Christensen, Tyler Christensen, Nicholas Colonnese, Stuart Dealey, Gaige DeHaven, Katie Doran, Chris Doughty, Robert Drury, Silvia Espino, Gabriel Geyne, Beth Goodrich, Kyra Gould, Joe Grisso, Susana Guerrero, Andrew Gwozdziowski, Monica Ha, Ehsan Hajiesmaili, Kate Healy, Rose Hope, Michael Hurst, Claire Ikemiya, Daisy Isibor, Rick James, Yashasvi Joginapally, Samuel Johnson, Tyler Jorgensen, Kristy Jost, Ben Kamath, Slava Karulin, Alexander Keener, Woo Kim, Alison Krauskopf, Ankit Kumar, Joshua Lang, Lizzy Li, Cameron Lynch, Daniel Ma, Hector Martinon, Christina Matos, Keagan McCurdy, Lee Mincey, Stuart Nezlek, Tiffany Nguyen, James O'Hara, Jason Osborne, Jacky Pai, Roham Pardakhtim, David Perek, Alexandre Poulin, Nick Raines, Salwa Rasheed, Leah Resneck, Kevin Rhodes, Ergys Ristani, Douglas Roberts, Anik Sarker, Harrison Scarborough, Jonas Schmidtler, Brian Shieh, Benjamin Shuman, Garrett Simard, Forrest Smith, Udara Somarathna, Eliot Sosin, Jonathan Stewart, Kristine Strom, Adam Swett, Hal Talbot-Mantooth, Julia Tanner, Sai Sharan Thirunagari, Curtis Torrey, Simge Uzun, Eileen Wachs, Rylan Wasson, Henry Wei, Jesse White, Beau Woodbyrne, Antonio Woods, Noah Young, Chandler Yount, Joseph Zhang, Sean Keller·· 1 days agoSignalEditorial score82

Tactus: Tactile & Pose Sensing Glove for Natural Dexterity Data Collection

Tactus: Tactile & Pose Sensing Glove for Natural Dexterity Data Collection

Summary

This research paper presents Tactus, a textile-integrated sensing glove that enables accurate contact force and hand pose sensing during natural manipulation. The glove is designed to minimize interference with human movement, featuring a thin 3D-knit form factor, capacitive tactile sensors, and IMU-fused pose tracking. It includes calibration pipelines and standardized benchmarking protocols for tactile force regression and hand pose estimation, achieving a minimum detectable force of 0.59 N and 11.0 mm fingertip keypoint relative error during occlusion.

Source: arXiv Robotics — research abstracts · Read original article ↗

Loading article text…

What the source reports

Publisher-reported claims, with original evidence. These results have not been independently verified by RoboSignal.

Reported numbers

  • minimum detectable force

    0.59

    View original evidence
    r knowledge the first quantitative cross-platform evaluation of this kind. Tactus resolves a minimum detectable force of 0.59 N at 95% confidence, 1.6 - 2.7x lower than the commercial baselines, and with 0.87 cross-participant consistency, while our pose tracking sustains 11.0 mm fingertip keypoint relative error during manipulation, when occlusion is heaviest. We show that these combined signals support object prope
    Open source S5
  • cross-participant consistency

    0.87

    View original evidence
    r knowledge the first quantitative cross-platform evaluation of this kind. Tactus resolves a minimum detectable force of 0.59 N at 95% confidence, 1.6 - 2.7x lower than the commercial baselines, and with 0.87 cross-participant consistency, while our pose tracking sustains 11.0 mm fingertip keypoint relative error during manipulation, when occlusion is heaviest. We show that these combined signals support object prope
    Open source S5
  • fingertip keypoint relative error

    11

    View original evidence
    r knowledge the first quantitative cross-platform evaluation of this kind. Tactus resolves a minimum detectable force of 0.59 N at 95% confidence, 1.6 - 2.7x lower than the commercial baselines, and with 0.87 cross-participant consistency, while our pose tracking sustains 11.0 mm fingertip keypoint relative error during manipulation, when occlusion is heaviest. We show that these combined signals support object prope
    Open source S5
  • force detectable improvement over commercial baselines

    1.6–2.7

    View original evidence
    r knowledge the first quantitative cross-platform evaluation of this kind. Tactus resolves a minimum detectable force of 0.59 N at 95% confidence, 1.6 - 2.7x lower than the commercial baselines, and with 0.87 cross-participant consistency, while our pose tracking sustains 11.0 mm fingertip keypoint relative error during manipulation, when occlusion is heaviest. We show that these combined signals support object prope
    Open source S5
  • fingertip stackup thickness

    1.5

    View original evidence
    ior. We present Tactus, a textile-integrated sensing glove that co-optimizes three design pillars: (1) a thin, conformal 3D-knit form factor (1.5 mm fingertip stackup) designed to minimize interference with natural manipulation, (2) strategically placed capacitive tactile sensors at manipulation-relevant regions informed by empirical contact studies, and (3) IMU-fused pose tracking that maintains accuracy through the
    Open source S3
  • number of design pillars

    3

    View original evidence
    ior. We present Tactus, a textile-integrated sensing glove that co-optimizes three design pillars: (1) a thin, conformal 3D-knit form factor (1.5 mm fingertip stackup) designed to minimize interference with natural manipulation, (2) strategically placed capacitive tactile sensors at manipulation-relevant regions informed by empirical contact studies, and (3) IMU-fused pose tracking that maintains accuracy through the
    Open source S3
  • number of commercial tactile gloves compared

    2

    View original evidence
    hand-object occlusions where manipulation data is most valuable. Tactus includes a documented calibration pipeline for cross-glove consistency and per-session calibration for subject-dependent correction. To enable objective comparison, we introduce standardized benchmarking protocols for tactile force regression and hand pose estimation, and apply them to Tactus and two commercially available tactile gloves - to ou
    Open source S4
  • paper: not_reported
  • code: not_reported
  • weights: not_reported
  • dataset: not_reported
Source excerpts and review record

Automatically extracted; no manual editorial approval recorded.

r knowledge the first quantitative cross-platform evaluation of this kind. Tactus resolves a minimum detectable force of 0.59 N at 95% confidence, 1.6 - 2.7x lower than the commercial baselines, and with 0.87 cross-participant consistency, while our pose tracking sustains 11.0 mm fingertip keypoint relative error during manipulation, when occlusion is heaviest. We show that these combined signals support object prope

Open source S5

ior. We present Tactus, a textile-integrated sensing glove that co-optimizes three design pillars: (1) a thin, conformal 3D-knit form factor (1.5 mm fingertip stackup) designed to minimize interference with natural manipulation, (2) strategically placed capacitive tactile sensors at manipulation-relevant regions informed by empirical contact studies, and (3) IMU-fused pose tracking that maintains accuracy through the

Open source S3

hand-object occlusions where manipulation data is most valuable. Tactus includes a documented calibration pipeline for cross-glove consistency and per-session calibration for subject-dependent correction. To enable objective comparison, we introduce standardized benchmarking protocols for tactile force regression and hand pose estimation, and apply them to Tactus and two commercially available tactile gloves - to ou

Open source S4

Source:arXiv Robotics — research abstracts · arxiv.org

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).