Reported quantity · mean error reduction: 0.5 other · Basis not reported · Differing source assertions
“mplements. On two robots with different waists, each without and with a payload, calibration reduces the mean errors on held-out poses from 11.3-31.1 mm to 0.50-1.11 mm. For every training-set size from 20 poses to all, the method has 17-63% lower mean errors than adaptations of two published whole-body calibration methods, mainly through the waist compliance. Independent calibration yields two waist models; using ei”
Exact source · revision 1Source owner not reported
Reported quantity · mean error reduction: 11.3 other · Basis not reported · Differing source assertions
“mplements. On two robots with different waists, each without and with a payload, calibration reduces the mean errors on held-out poses from 11.3-31.1 mm to 0.50-1.11 mm. For every training-set size from 20 poses to all, the method has 17-63% lower mean errors than adaptations of two published whole-body calibration methods, mainly through the waist compliance. Independent calibration yields two waist models; using ei”
Exact source · revision 1Source owner not reported
Reported quantity · error increase: 3.21 other · Basis not reported
“ther for both arms raises the other arm's error to up to 3.21 mm.”
Exact source · revision 1Source owner not reported
Reported quantity · training set size: 20 other · Basis not reported
“mplements. On two robots with different waists, each without and with a payload, calibration reduces the mean errors on held-out poses from 11.3-31.1 mm to 0.50-1.11 mm. For every training-set size from 20 poses to all, the method has 17-63% lower mean errors than adaptations of two published whole-body calibration methods, mainly through the waist compliance. Independent calibration yields two waist models; using ei”
Exact source · revision 1Source owner not reported
Report timeline
Follow attributed reports and material updates.
- arXiv Robotics — research abstractsSignalWhole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain Model
This research introduces a shared-waist dual-chain calibration framework for wheeled humanoid robots equipped with arms on a single actuated waist and lacking torque sensors.
Timezone · UTC
Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).