Skip to content
Trending eventHistorical event

Flexible Piezoelectric Tactile Sensing System for Intelligent Object Recognition

1 reports1 reporting sourcesUpdated 4 days ago

Overview

Event synthesis

This research presents a flexible, distributed piezoelectric tactile sensing system designed for early-stage object recognition during robotic grasping.

Generated from attributed reports · Updated 2 days ago

Event evidence and corrections

0 attributed source owners. Ownership does not establish independent confirmation. Quantities are reported separately and are never added together.

Reported quantity · recognition latency: 101 other · Basis not reported
Supporting report

“samples), was deployed on an embedded edge platform, achieving an end-to-end recognition latency of approximately 101 ms from contact onset and an energy consumption of 63.8 microjoules per inference. These results demonstrate the potential of distributed piezoelectric tactile sensing for accurate, energy-efficient, and real-time object recognition during robotic grasping.”

Exact source · revision 1

Source owner not reported

Reported quantity · energy consumption: 63.8 other · Basis not reported
Supporting report

“samples), was deployed on an embedded edge platform, achieving an end-to-end recognition latency of approximately 101 ms from contact onset and an energy consumption of 63.8 microjoules per inference. These results demonstrate the potential of distributed piezoelectric tactile sensing for accurate, energy-efficient, and real-time object recognition during robotic grasping.”

Exact source · revision 1

Source owner not reported

Reported quantity · F1-score: 0.9796 other · Basis not reported · Differing source assertions
Supporting report

“ion accuracy and real-time feasibility were systematically investigated. Increasing the number of sensing elements improved recognition performance across all approaches. The best-performing method, based on spatiotemporal heatmaps and a 2D-CNN, achieved F1-scores of 0.9796, 0.9846, and 0.9903 using 16, 24, and 32 sensors, respectively. The optimal configuration, comprising 32 sensors and a 100-ms temporal window (50”

Exact source · revision 1

Source owner not reported

Reported quantity · F1-score: 0.9846 other · Basis not reported · Differing source assertions
Supporting report

“ion accuracy and real-time feasibility were systematically investigated. Increasing the number of sensing elements improved recognition performance across all approaches. The best-performing method, based on spatiotemporal heatmaps and a 2D-CNN, achieved F1-scores of 0.9796, 0.9846, and 0.9903 using 16, 24, and 32 sensors, respectively. The optimal configuration, comprising 32 sensors and a 100-ms temporal window (50”

Exact source · revision 1

Source owner not reported

Reported quantity · F1-score: 0.9903 other · Basis not reported · Differing source assertions
Supporting report

“ion accuracy and real-time feasibility were systematically investigated. Increasing the number of sensing elements improved recognition performance across all approaches. The best-performing method, based on spatiotemporal heatmaps and a 2D-CNN, achieved F1-scores of 0.9796, 0.9846, and 0.9903 using 16, 24, and 32 sensors, respectively. The optimal configuration, comprising 32 sensors and a 100-ms temporal window (50”

Exact source · revision 1

Source owner not reported

Reported quantity · sensor count: 16 other · Basis not reported · Differing source assertions
Supporting report

“ion accuracy and real-time feasibility were systematically investigated. Increasing the number of sensing elements improved recognition performance across all approaches. The best-performing method, based on spatiotemporal heatmaps and a 2D-CNN, achieved F1-scores of 0.9796, 0.9846, and 0.9903 using 16, 24, and 32 sensors, respectively. The optimal configuration, comprising 32 sensors and a 100-ms temporal window (50”

Exact source · revision 1

Source owner not reported

Reported quantity · sensor count: 24 other · Basis not reported · Differing source assertions
Supporting report

“ion accuracy and real-time feasibility were systematically investigated. Increasing the number of sensing elements improved recognition performance across all approaches. The best-performing method, based on spatiotemporal heatmaps and a 2D-CNN, achieved F1-scores of 0.9796, 0.9846, and 0.9903 using 16, 24, and 32 sensors, respectively. The optimal configuration, comprising 32 sensors and a 100-ms temporal window (50”

Exact source · revision 1

Source owner not reported

Reported quantity · sensor count: 32 other · Basis not reported · Differing source assertions
Supporting report

“ion accuracy and real-time feasibility were systematically investigated. Increasing the number of sensing elements improved recognition performance across all approaches. The best-performing method, based on spatiotemporal heatmaps and a 2D-CNN, achieved F1-scores of 0.9796, 0.9846, and 0.9903 using 16, 24, and 32 sensors, respectively. The optimal configuration, comprising 32 sensors and a 100-ms temporal window (50”

Exact source · revision 1

Source owner not reported

Report timeline

Follow attributed reports and material updates.

11/6
  1. arXiv Robotics — research abstractsSignal
    Flexible Piezoelectric Tactile Sensing System for Intelligent Object Recognition

    This research presents a flexible, distributed piezoelectric tactile sensing system designed for early-stage object recognition during robotic grasping.

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).