Calibration of Neuromusculoskeletal Models Using Differentiable Physics: Recommendations for Improving Model Accuracy

1 reports1 reporting sourcesUpdated 1 days ago

Overview

Event synthesis

This research paper evaluates various modules for calibrating human neuromusculoskeletal models using differentiable physics. By comparing 16 configurations on a differentiable upper limb model across four subjects, the authors find that incorporating muscle synergy extrapolation reduces average torque loss by 23.6% and bone dynamic parameter optimization reduces it by 10.9%. The study recommends integrating these two modules to improve model accuracy and narrow the gap between simulation and reality.

Generated from attributed reports · Updated 3 hours ago

Event evidence and corrections

0 attributed source owners. Ownership does not establish independent confirmation. Quantities are reported separately and are never added together.

Reported quantity · number of calibrations configurations: 16 other · reported trials
Supporting report

“elbow, and 11 superficial and 5 deep muscles in the calibration to find an optimal pipeline for improving model accuracy. The considered modules include muscle synergy, learnable bone parameters, optimizable geometry of wrap objects, and constraint torque of the differentiable arm model. To evaluate the effect and interplay between the modules on calibration accuracy, one or more modules were used in each of 16 calib”

Exact source · revision 1

Source owner not reported

Reported quantity · number of testing movements: 9 other · Basis not reported
Supporting report

“ration configurations, which were compared in terms of the error between two joint torques calculated by the forward and inverse dynamics with the calibrated model on 9 distinctive testing movements across 4 subjects. Results showed that torque loss was reduced by 23.6% on average using muscle synergy extrapolation to estimate deep muscle activities, and by 10.9% on average through bone dynamic parameter optimization”

Exact source · revision 1

Source owner not reported

Reported quantity · number of subjects: 4 other · Basis not reported
Supporting report

“ration configurations, which were compared in terms of the error between two joint torques calculated by the forward and inverse dynamics with the calibrated model on 9 distinctive testing movements across 4 subjects. Results showed that torque loss was reduced by 23.6% on average using muscle synergy extrapolation to estimate deep muscle activities, and by 10.9% on average through bone dynamic parameter optimization”

Exact source · revision 1

Source owner not reported

Reported quantity · number of DoF in shoulder: 3 other · Basis not reported
Supporting report

“ptimizers have enabled calibration of increasingly sophisticated human models with a large number of parameters, which seek to narrow the gap between simulation and reality. Several modules have been evaluated separately in different studies, but have never been directly compared within the same study. In this work, these modules are compared on the same differentiable upper limb model with a 3-DoF shoulder, a 2-DoF”

Exact source · revision 1

Source owner not reported

Report timeline

Follow attributed reports and material updates.

11/25
  1. arXiv Robotics — research abstractsSignal
    Calibration of Neuromusculoskeletal Models Using Differentiable Physics: Recommendations for Improving Model Accuracy

    This research paper evaluates various modules for calibrating human neuromusculoskeletal models using differentiable physics. By comparing 16 configurations on a differentiable upper limb model across four subjects, the authors find that incorporating muscle synergy extrapolation reduces average torque loss by 23.6% and bone dynamic parameter optimization reduces it by 10.9%. The study recommends integrating these two modules to improve model accuracy and narrow the gap between simulation and reality.