Real-time Visualization Enhancement for Minimally Invasive Surgery

1 reports1 reporting sourcesUpdated 5 days ago

Overview

Event synthesis

A hybrid framework improves occlusion handling and depth tracking in MIS with 81.95% occlusion detection accuracy and 0.53 cm depth RMSE. Surgeon feedback highlights clinical relevance for intraoperative navigation. (arXiv, 2026-10-14).

Generated from attributed reports · Updated 3 hours ago

Event evidence and corrections

0 attributed source owners. Ownership does not establish independent confirmation. Quantities are reported separately and are never added together.

Reported quantity · confidence score: 0.85 other · Basis not reported
Supporting report

“cular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation ag”

Exact source · revision 1

Source owner not reported

Reported quantity · mean absolute error: 0.34 other · Basis not reported · Differing source assertions
Supporting report

“cular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation ag”

Exact source · revision 1

Source owner not reported

Reported quantity · root mean square error: 0.53 other · Basis not reported · Differing source assertions
Supporting report

“cular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation ag”

Exact source · revision 1

Source owner not reported

Reported quantity · mean absolute error: 0.65 other · Basis not reported · Differing source assertions
Supporting report

“ainst stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.”

Exact source · revision 1

Source owner not reported

Reported quantity · root mean square error: 0.66 other · Basis not reported · Differing source assertions
Supporting report

“ainst stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.”

Exact source · revision 1

Source owner not reported

Reported quantity · frames per second: 38.7 other · Basis not reported
Supporting report

“ainst stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.”

Exact source · revision 1

Source owner not reported

Report timeline

Follow attributed reports and material updates.

10/14
  1. arXiv Robotics — research abstracts
    Real-time Visualization Enhancement for Minimally Invasive Surgery Using Particle Filtering and Depth-aware Occlusion Handling

    A hybrid framework improves occlusion handling and depth tracking in MIS. It achieves 81.95% occlusion detection accuracy and 0.53 cm depth RMSE. Surgeon feedback highlights clinical relevance for intraoperative navigation.

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).