Skip to content
Trending eventWatching

SyncHeC: Markerless Spatio-Temporal Hand-Eye Calibration via Differentiable and

1 reports1 reporting sourcesUpdated 1 days ago

Overview

Event synthesis

This research introduces SyncHeC, a framework for markerless hand-eye calibration that jointly estimates camera geometry and time offsets from continuous robot motion using differentiable rendering. Evaluated on a 7-DoF arm, the method achieves 0.21 cm translation error and 2.7 ms latency error against reference benchmarks, outperforming CM-Calib by 3.7x in translation and 2.3x in latency. The approach supports Eye-to-Hand, Eye-in-Hand, and multi-camera setups across seven arms and four depth sensors, with policy training integration showing an 8.1 percentage point increase in success rates across six task families.

Generated from attributed reports · Updated 2 hours ago

Event evidence and corrections

0 attributed source owners. Ownership does not establish independent confirmation. Quantities are reported separately and are never added together.

Reported quantity · translation error: 0.21 other · Basis not reported
Supporting report

“ic depth complements mask contours, and an offline planner combines spatial sensitivity with temporal excitation. Alternating updates support Eye-to-Hand, Eye-in-Hand, and multi-camera calibration. On a 7-DoF arm, one $6.5$\,s motion yields $0.21$\,cm translation error against a marker-board reference, $0.34$\,cm touch-test error, and $2.7$\,ms latency error relative to an $87$\,ms reference with $95\%$ uncertainty o”

Exact source · revision 1

Source owner not reported

Reported quantity · touch-test error: 0.34 other · Basis not reported
Supporting report

“ic depth complements mask contours, and an offline planner combines spatial sensitivity with temporal excitation. Alternating updates support Eye-to-Hand, Eye-in-Hand, and multi-camera calibration. On a 7-DoF arm, one $6.5$\,s motion yields $0.21$\,cm translation error against a marker-board reference, $0.34$\,cm touch-test error, and $2.7$\,ms latency error relative to an $87$\,ms reference with $95\%$ uncertainty o”

Exact source · revision 1

Source owner not reported

Reported quantity · latency error: 2.7 other · Basis not reported
Supporting report

“ic depth complements mask contours, and an offline planner combines spatial sensitivity with temporal excitation. Alternating updates support Eye-to-Hand, Eye-in-Hand, and multi-camera calibration. On a 7-DoF arm, one $6.5$\,s motion yields $0.21$\,cm translation error against a marker-board reference, $0.34$\,cm touch-test error, and $2.7$\,ms latency error relative to an $87$\,ms reference with $95\%$ uncertainty o”

Exact source · revision 1

Source owner not reported

Reported quantity · translation error improvement factor: 3.7 other · Basis not reported
Supporting report

“f $\pm1.5$\,ms. Against CM-Calib on matched recordings, translation and nominal latency errors improve by $3.7\times$ and $2.3\times$. Experiments span seven arms and four depth sensors. Compensating the recovered offset during policy training and deployment increases success by $8.1$ percentage points across six families and six tasks ($1{,}800$ matched pairs; paired $95\%$ confidence interval $[6.3,9.9]$ points).”

Exact source · revision 1

Source owner not reported

Reported quantity · latency error improvement factor: 2.3 other · Basis not reported
Supporting report

“f $\pm1.5$\,ms. Against CM-Calib on matched recordings, translation and nominal latency errors improve by $3.7\times$ and $2.3\times$. Experiments span seven arms and four depth sensors. Compensating the recovered offset during policy training and deployment increases success by $8.1$ percentage points across six families and six tasks ($1{,}800$ matched pairs; paired $95\%$ confidence interval $[6.3,9.9]$ points).”

Exact source · revision 1

Source owner not reported

Report timeline

Follow attributed reports and material updates.

11/3
  1. arXiv Robotics — research abstractsSignal
    SyncHeC: Markerless Spatio-Temporal Hand-Eye Calibration via Differentiable Rendering and Continuous-Time Joint Optimization

    This research introduces SyncHeC, a framework for markerless hand-eye calibration that jointly estimates camera geometry and time offsets from continuous robot motion using differentiable rendering. Evaluated on a 7-DoF arm, the method achieves 0.21 cm translation error and 2.7 ms latency error against reference benchmarks, outperforming CM-Calib by 3.7x in translation and 2.3x in latency. The approach supports Eye-to-Hand, Eye-in-Hand, and multi-camera setups across seven arms and four depth sensors, with policy training integration showing an 8.1 percentage point increase in success rates across six task families.

Event coverage history

There is not enough continuous observation data to show a trend.

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).