Compressed Orientation Reachability Maps for Sub-Second Robotic Needle Entry Point Planning
Compressed Orientation Reachability Maps for Sub-Second Robotic Needle Entry Point Planning
This research presents an Orientation-Based Reachability Map (ORM) that enables sub-second robotic needle entry point planning for liver interventions. The ORM precomputes kinematic feasibility across 188,873 workspace positions and uses a JIT compiled runtime pipeline to achieve planning latencies of 0.289-0.349 seconds per target, significantly faster than existing methods which take 13.5-26.9 seconds. The approach maintains high geometric fidelity with mean convex hull and alpha-shape overlap ratios of 0.933 and 0.976 respectively.
This paper introduces an efficient method for robotic needle entry point planning in liver interventions, reducing planning latency from seconds to sub-second levels using a precomputed orientation reachability map.
Source: arXiv Robotics — research abstracts · Read original article ↗
Loading article text…
What the source reports
Publisher-reported claims, with original evidence. These results have not been independently verified by RoboSignal.
Reported numbers
planning latency
0.289–0.349
View original evidence
on in planning latency from 13.5-26.9 s to 0.289-0.349 s per target while maintaining high geometric fidelity, achieving a mean convex hull volume overlap ratio of 0.933 and a mean alpha-shape volume ratio of 0.976 relative to the baseline reachable point cloud. The proposed ORM framework enables sub-second entry point planning and provides an efficient computational framework for robotic needle insertion in percutan
Open source S4mean convex hull volume overlap ratio
0.933
View original evidence
on in planning latency from 13.5-26.9 s to 0.289-0.349 s per target while maintaining high geometric fidelity, achieving a mean convex hull volume overlap ratio of 0.933 and a mean alpha-shape volume ratio of 0.976 relative to the baseline reachable point cloud. The proposed ORM framework enables sub-second entry point planning and provides an efficient computational framework for robotic needle insertion in percutan
Open source S4mean alpha-shape volume ratio
0.976
View original evidence
on in planning latency from 13.5-26.9 s to 0.289-0.349 s per target while maintaining high geometric fidelity, achieving a mean convex hull volume overlap ratio of 0.933 and a mean alpha-shape volume ratio of 0.976 relative to the baseline reachable point cloud. The proposed ORM framework enables sub-second entry point planning and provides an efficient computational framework for robotic needle insertion in percutan
Open source S4workspace positions
188,873
View original evidence
paper introduces an Orientation-Based Reachability Map (ORM) that precomputes the kinematic feasibility of a 6 Degrees of Freedom (DoF) serial manipulator across 188,873 workspace positions and encodes orientation feasibility into a compact, indexed 83 MB map. A Just-In-Time (JIT) compiled runtime pipeline replaces live optimization with near-instantaneous array lookups. Experimental evaluation demonstrates a reducti
Open source S3map size
83
View original evidence
paper introduces an Orientation-Based Reachability Map (ORM) that precomputes the kinematic feasibility of a 6 Degrees of Freedom (DoF) serial manipulator across 188,873 workspace positions and encodes orientation feasibility into a compact, indexed 83 MB map. A Just-In-Time (JIT) compiled runtime pipeline replaces live optimization with near-instantaneous array lookups. Experimental evaluation demonstrates a reducti
Open source S3
- paper: not_reported
- code: not_reported
- weights: not_reported
- dataset: not_reported
Source excerpts and review record
Automatically extracted; no manual editorial approval recorded.
arXiv:2610.39879v1 Announce Type: new Abstract: In the context of multi-stage trajectory planning for robotic percutaneous liver interventions, identifying a kinematically feasible entry point remains a critical computational bottleneck. Existing methods rely on exhaustive inverse kinematics or randomized searches, incurring delays of 13 to 27 seconds per target and limiting real-time intraoperative adaptation. This
Open source S2
on in planning latency from 13.5-26.9 s to 0.289-0.349 s per target while maintaining high geometric fidelity, achieving a mean convex hull volume overlap ratio of 0.933 and a mean alpha-shape volume ratio of 0.976 relative to the baseline reachable point cloud. The proposed ORM framework enables sub-second entry point planning and provides an efficient computational framework for robotic needle insertion in percutan
Open source S4
paper introduces an Orientation-Based Reachability Map (ORM) that precomputes the kinematic feasibility of a 6 Degrees of Freedom (DoF) serial manipulator across 188,873 workspace positions and encodes orientation feasibility into a compact, indexed 83 MB map. A Just-In-Time (JIT) compiled runtime pipeline replaces live optimization with near-instantaneous array lookups. Experimental evaluation demonstrates a reducti
Open source S3
Source:arXiv Robotics — research abstracts · arxiv.org