Skip to content
Trending eventWatching

Compressed Orientation Reachability Maps for Sub-Second Robotic Needle Entry

1 reports1 reporting sourcesUpdated 2 days ago

Overview

Report summary

This research presents an Orientation-Based Reachability Map (ORM) that enables sub-second robotic needle entry point planning for liver interventions. The ORM precomputes kinematic feasibility across 188,873 workspace positions and uses a JIT compiled runtime pipeline to achieve planning latencies of 0.289-0.349 seconds per target, significantly faster than existing methods which take 13.5-26.9 seconds. The approach maintains high geometric fidelity with mean convex hull and alpha-shape overlap ratios of 0.933 and 0.976 respectively.

From arXiv Robotics — research abstracts

Event evidence and corrections

0 attributed source owners. Ownership does not establish independent confirmation. Quantities are reported separately and are never added together.

Reported quantity · planning latency: 0.289 other · Basis not reported
Supporting report

“on in planning latency from 13.5-26.9 s to 0.289-0.349 s per target while maintaining high geometric fidelity, achieving a mean convex hull volume overlap ratio of 0.933 and a mean alpha-shape volume ratio of 0.976 relative to the baseline reachable point cloud. The proposed ORM framework enables sub-second entry point planning and provides an efficient computational framework for robotic needle insertion in percutan”

Exact source · revision 1

Source owner not reported

Reported quantity · mean convex hull volume overlap ratio: 0.933 other · Basis not reported
Supporting report

“on in planning latency from 13.5-26.9 s to 0.289-0.349 s per target while maintaining high geometric fidelity, achieving a mean convex hull volume overlap ratio of 0.933 and a mean alpha-shape volume ratio of 0.976 relative to the baseline reachable point cloud. The proposed ORM framework enables sub-second entry point planning and provides an efficient computational framework for robotic needle insertion in percutan”

Exact source · revision 1

Source owner not reported

Reported quantity · mean alpha-shape volume ratio: 0.976 other · Basis not reported
Supporting report

“on in planning latency from 13.5-26.9 s to 0.289-0.349 s per target while maintaining high geometric fidelity, achieving a mean convex hull volume overlap ratio of 0.933 and a mean alpha-shape volume ratio of 0.976 relative to the baseline reachable point cloud. The proposed ORM framework enables sub-second entry point planning and provides an efficient computational framework for robotic needle insertion in percutan”

Exact source · revision 1

Source owner not reported

Reported quantity · workspace positions: 188873 other · Basis not reported
Supporting report

“paper introduces an Orientation-Based Reachability Map (ORM) that precomputes the kinematic feasibility of a 6 Degrees of Freedom (DoF) serial manipulator across 188,873 workspace positions and encodes orientation feasibility into a compact, indexed 83 MB map. A Just-In-Time (JIT) compiled runtime pipeline replaces live optimization with near-instantaneous array lookups. Experimental evaluation demonstrates a reducti”

Exact source · revision 1

Source owner not reported

Reported quantity · map size: 83 other · Basis not reported
Supporting report

“paper introduces an Orientation-Based Reachability Map (ORM) that precomputes the kinematic feasibility of a 6 Degrees of Freedom (DoF) serial manipulator across 188,873 workspace positions and encodes orientation feasibility into a compact, indexed 83 MB map. A Just-In-Time (JIT) compiled runtime pipeline replaces live optimization with near-instantaneous array lookups. Experimental evaluation demonstrates a reducti”

Exact source · revision 1

Source owner not reported

Evidence dependency changes (1)
  • 2026-10-31T17:57:57.964Z · evidence updated · source revision 1. Evidence extraction was updated; current source attributions are shown above.

Report timeline

Follow attributed reports and material updates.

10/30
  1. arXiv Robotics — research abstractsSignal
    Compressed Orientation Reachability Maps for Sub-Second Robotic Needle Entry Point Planning

    This research presents an Orientation-Based Reachability Map (ORM) that enables sub-second robotic needle entry point planning for liver interventions. The ORM precomputes kinematic feasibility across 188,873 workspace positions and uses a JIT compiled runtime pipeline to achieve planning latencies of 0.289-0.349 seconds per target, significantly faster than existing methods which take 13.5-26.9 seconds. The approach maintains high geometric fidelity with mean convex hull and alpha-shape overlap ratios of 0.933 and 0.976 respectively.

Event coverage history

There is not enough continuous observation data to show a trend.

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).