Skip to content
arXiv Robotics — research abstracts· Jinshi Zhao, Libaihe Tian, Alex Ranne, Qindong Zheng, Yue Li, Xiaotong Guo, Ziqi Yang, Ali Anil Demircali, Mohamed E. M. K. Abdelaziz, Bruno Gil Rosa, Ferdinando Rodriguez y Baena, Burak Temelkuran·· 7 days agoEditorial score65

Selectively Actuated Fiberbots for High-precision Minimally Invasive Surgery

Selectively Actuated Fiberbots for High-precision Minimally Invasive Surgery

Summary

This paper presents an electrothermally actuated fiber-based robot designed for minimally invasive surgery (MIS). The robot uses Joule heating in a distal active segment to achieve precise manipulation, with a diameter of 1.9 mm and length of 1.2 m. It can operate independently within endoscopic systems, offering potential improvements in surgical precision.

Source: arXiv Robotics — research abstracts · Read original article ↗

Loading article text…

What the source reports

Publisher-reported claims, with original evidence. These results have not been independently verified by RoboSignal.

Reported numbers

  • fiber diameter

    1.9

    View original evidence
    er is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 $\mu$m. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allo
    Open source S3
  • fiber length

    1.2

    View original evidence
    er is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 $\mu$m. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allo
    Open source S3
  • positional precision

    <100

    View original evidence
    er is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 $\mu$m. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allo
    Open source S3
  • paper: not_reported
  • code: not_reported
  • weights: not_reported
  • dataset: not_reported

What remains unknown

Not established in the collected evidence: Environment, Control, Data origin.

Reported performance applies to the described task. It does not establish general autonomy or deployment readiness.

Source excerpts and review record

Automatically extracted; no manual editorial approval recorded.

er is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 $\mu$m. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allo

Open source S3

w independent motion. A phantom demonstration combining the robotic fiber with a da Vinci instrument conceptually demonstrated its compatibility with existing endoscopic systems for clinical applications. Our robotic fiber enables precise distal motion and holds the potential to improve clinical outcomes by enhancing precision in MIS procedures.

Open source S4

Source:arXiv Robotics — research abstracts · arxiv.org

Timezone · UTC

Article dates follow your selected timezone. Briefing editions use Hong Kong time (UTC+8).